Sensing Puck needs to be buried 13 cm to 20 cm in ground. Cable needs to go in a conduit. There are three Sensitivity adjustment inside the Puck.
Install CP-4 at least:
- 6-10 feet away from buried power, telephone, or invisible dog fence
- 10 feet away from natural gas lines
- 20 feet away from power pole with a transformer
- 100 feet back from railroad traffic
- 200 feet away from high power substation power lines
- 80-100 feet back from gate operator
Specifications:
- Power Required 8–24 VAC or 8–30 VDC
- Relay Time 2–3 seconds
- Relay Contacts SPDT, floating, N.O. or N.C. (Form C)
- Relay Contact Rating 1 amp/24 VDC (1 mA at 5 VDC min. load)
- Enclosure Rating IP68
- Strength Rating 9.53 ton-force 8646 kgf
- Temperature Range -25° F. – +140° F. -32° C. – 60° C.
- Dimensions 11.43 cm dia. x 6.35 cm high
- Weight 5 lbs. (2.7 KG) with 100 ft. cable
Watch Application and Wiring Videos here